Hello. I have 2 sets of solar panels (200W each) with their own regulator, and a wind generator with its own regulator. However they are not all charging efficiently. Even though the battery bank is fla,t when it is sunny and windy the wind regulator slows the wind gen down and one solar reg beats the other down. So I am getting maximum recharging from only one source not all 3. I think the regulators are sensing the charging voltage of the dominant regulator and thinking the battery is fully charged. Any suggestions? I have been looking for a regulator to manage 3 inputs (and 2 outputs would be good) but can't see any. Could I wire all 3 regulators to a 4th regulator for the bank? Thanks. Stephen.
Hi Stephen. You are right that whenever you are charging a battery, the voltage will increase, and therefore any other charging sources attached to the battery will see a higher voltage and think the batteries are slightly more highly charged than they actually are. That's pretty much unavoidable.
The effect should not be very large, however, and it's not necessarily a bad thing, as it prevents overcharging. PV arrays trickle charge batteries, and with a healthy battery bank and decent sized cables between the battery and regulators, you shouldn't see a massive voltage increase. If you are - if they are cutting out even when you think the batteries are flat - it's suggesting the voltage is rising above 14.4V (the usual cut off), even with a relatively low charging current. That suggests to me that the batteries are on the way out.
Regulators are designed to be used in parallel in the way you have them wired, so I very much doubt you will find any difference if you do change the regulators. Trying new batteries is in my opinion far more likely to give you good results.
Hope that helps.